News

What special requirements need to be met when Round Pre-Insulated Terminal is used in high-voltage circuits?

Publish Time: 2024-08-08
Round Pre-Insulated Terminal plays a vital role in high-voltage circuits, and it needs to meet a series of special requirements to ensure the safety and stable operation of the circuit.

First, insulation performance is the key. In high-voltage environments, the insulation material of the terminal must have extremely high compressive strength to effectively prevent current leakage and arcing. It needs to be able to withstand the high-voltage electric field without being broken down, and generally uses high-quality insulating plastics, such as polyvinyl chloride with good insulation and heat resistance. At the same time, the thickness of the insulation layer should be moderate and uniform to ensure reliable insulation protection in different parts.

Secondly, the mechanical strength should be high. High-voltage circuits may face external forces such as vibration and stretching, and Round Pre-Insulated Terminal needs to have sufficient mechanical strength to maintain the stability of the connection. The metal part of the terminal should be made of high-strength conductive materials, such as copper alloys, and its structural design should be reasonable to firmly clamp the wires to prevent loosening or falling off.

In addition, in terms of electrical performance, the contact resistance of the terminal should be as small as possible. In the case of high voltage and high current, excessive contact resistance will cause serious heating and even fire. Therefore, the contact surface of the terminal should be precisely processed to ensure good contact to reduce the contact resistance.

In addition, temperature resistance should not be ignored. When the high-voltage circuit is running, a certain amount of heat will be generated. The terminal should be able to work normally in a high-temperature environment without affecting its performance. It needs to have good thermal stability and will not deform or reduce insulation performance within a certain temperature range.

Finally, there are strict requirements for the installation and maintenance of Round Pre-Insulated Terminal in high-voltage circuits. During installation, the standardized operating procedures must be followed to ensure that the terminal connection is correct. In terms of maintenance, the insulation status of the terminal, the tightness of the connection, etc. should be checked regularly to promptly discover and deal with potential problems to ensure the safe and reliable operation of the high-voltage circuit. In short, only by meeting these special requirements can the Round Pre-Insulated Terminal play its due role in the high-voltage circuit.
×

Contact Us